Standard Linear Power Supplies
Description |
|
The International Power “open frame series” are a high reliability line of regulated open frame linear AC to DC power supplies designed to operate over the wide range of AC power sources found worldwide. This feature simplifies your inventory and service consideration by allowing the use of one standard power supply regardless of the destination. These models are designed to meet many domestic and international regulatory agency requirements. If you plan to distribute your products worldwide, obtaining necessary agency approvals can be greatly simplified by specifying our International Power “open frame series”. | |
Features |
|
|
|
Linear Power Supply General Specifications |
|
· AC Input: 100/120/220/240 VAC +10%, -13%. 47-63 Hz. Tolerance for 230 VAC operation is +15%, -10%.Derate output current 10% for 50 Hz operation. See chassis AC connection table for jumper and line fusing requirements.
· DC Output: See Voltage/Current Rating Charts.Adjustment range ±5% minimum.Voltage nonadjustable on “3 terminal regulator” outputs of models IHAD12 and IHAD15. · Line Regulation: ±.05% for a 10% line change. Exceptions:±.01% for F case models±1% for IHAD12 and IHAD15±0.5% for all other outputs using 3 terminal regulators. · Load Regulation: ±.05% for a 50% load change. Exceptions:±.02% for F case models±1% for IHAD12 and IHAD15±0.5% for all other outputs using “3 terminal regulators. · Output Ripple: 5 Volt to 28 Volt units: 5mV pk-pk maximum 48 Volt to 155 Volt units: .02% pk-pk maximum 200 Volt & 250 Volt units: .05% pk-pk maximum 3 Terminal Regulator units: 0.2% pk-pk maximum · Transient Response: Less than 50µsec for a 50% load change. · Short Circuit and Overload Protection: Automatic current limit/foldback. · Overvoltage Protection: Provided on 5V outputs where indicated set at 6.3V ±0.4V. Other outputs use optional overvoltage protectors IOVP12 and IOVP24. · Remote Sensing: See Voltage/Current Rating Charts. Provided on outputs where indicated. |
· Stability: ±0.3% for 24 hours after 1 hr. warm-up.
· Temperature Ratings: Operating:0ºC to 50ºC full rated, derated linearly to 40% at 70ºC.(Recommended forced air at 200W, 50 CFM required at 250W) · Storage: -40ºC to 85ºC · Temperature Coefficient: 0.01%/ºC typical, .03%/ºC maximum. · Efficiency (typical): 5V outputs = 45%, 12V and 15V outputs = 55% and 24V through 250V outputs are 60%. · Master/Slave Operation: Provided on F case models only. For parallel operation of up to 6 units. · Vibration: Random vibration from 10Hz to 2KHz, 6.15grms (3 axis). · Shock: Operating 20G peak acceleration. · EMI/RFI: These linear power supplies have inherently low conducted and radiated noise levels. For most system applications they will meet the requirements of (FCC) 47CFR15J and EN55022. · Safety Agency Certifications: UL: 1950, Third Edition CUL: CAN/CSA C22.2 No. 950-95, IEC950 CE Mark: LVD 73/23/EEC · Leakage Current & Dielectric Withstand Leakage current is less than 50µA. Field terminal to terminal spacing is 5.25 mm with 9.0 mm creepage to other metal. Dielectric withstand voltages are 3750 VAC input to chassis, 3750 VAC input to output and 750 VDC output to chassis. UL tested at 4242 VDC input to output, 2121 VDC input to dead metal. |
Single Output Power Supplies
POWER SUPPLY MODEL (Click for Spec Sheet) |
OUTPUT |
CASE SIZE |
NOTES |
|
Volts |
Amps |
Click on code for Case details |
||
5 |
1.2 |
Not International Series |
||
IHA5-1.5/OVP |
5 |
1.5 |
Remote Sense Provided |
|
5 |
3 |
Remote Sense Provided |
||
5 |
6 |
Remote Sense Provided |
||
5 |
9 |
Remote Sense Provided |
||
IHD5-12/OVP |
5 |
12 |
Remote Sense Provided |
|
IHE5-18/OVP |
5 |
18 |
Remote Sense Provided |
|
IF5-25/OVP |
5 |
25 |
Remote Sense Provided |
|
IG5-35/OVP |
5 |
35 |
Remote Sense Provided |
|
ICP197 |
5 |
50 |
Remote Sense Provided |
|
IHA15-0.5 |
12 |
0.5 |
Not International Series |
|
IHA15-0.9 |
12 |
0.9 |
Remote Sense Provided |
|
12 |
1.7 |
Remote Sense Provided |
||
IHC12-3.4 |
12 |
3.4 |
Remote Sense Provided |
|
IHN12-5.1 |
12 |
5.1 |
Remote Sense Provided |
|
12 |
6.8 |
Remote Sense Provided |
||
IHE12-10.2 |
12 |
10.2 |
Remote Sense Provided |
|
IF15-15 |
12 |
16 |
Remote Sense Provided |
|
IHA15-0.5 |
15 |
0.5 |
Not International Series |
|
IHA15-0.9 |
15 |
0.9 |
||
15 |
1.5 |
Remote Sense Provided |
||
IHC15-3 |
15 |
3 |
Remote Sense Provided |
|
IHN15-4.5 |
15 |
4.5 |
Remote Sense Provided |
|
15 |
6 |
Remote Sense Provided |
||
15 |
9 |
Remote Sense Provided |
||
IF15-15 |
15 |
15 |
Remote Sense Provided |
|
IHA24-0.5 |
24 |
0.5 |
Remote Sense Provided |
|
24 |
1.2 |
Remote Sense Provided |
||
IHC24-2.4 |
24 |
2.4 |
Remote Sense Provided |
|
24 |
3.6 |
Remote Sense Provided |
||
24 |
4.8 |
Remote Sense Provided |
||
IHE24-7.2 |
24 |
7.2 |
Remote Sense Provided |
|
24 |
12 |
Remote Sense Provided |
||
IHA24-0.5 |
28 |
0.5 |
Remote Sense Provided |
|
28 |
1 |
Remote Sense Provided |
||
IHC28-2 |
28 |
2 |
Remote Sense Provided |
|
28 |
3 |
Remote Sense Provided |
||
IHD28-4 |
28 |
4 |
Remote Sense Provided |
|
28 |
6 |
Remote Sense Provided |
||
28 |
10 |
Remote Sense Provided |
||
48 |
0.5 |
|||
IHB48-0.5-105 |
48 |
0.75 |
||
IHC48-1 |
48 |
1 |
||
IHC48-1-105 |
48 |
1.5 |
||
48 |
3 |
Remote Sense Provided |
||
IHE48-4 |
48 |
4 |
Remote Sense Provided |
|
IF48-8 |
48 |
8 |
Not International Series |
|
100 – 135 |
0.2 |
Adjustable Range 100-135 |
||
135 – 170 |
0.12 |
Adjustable Range 135-170 |
||
IHB200-0.12 |
175 – 210 |
0.12 |
Adjustable Range 175-210 |
|
IHB250-0.1 |
215 – 265 |
0.1 |
Adjustable Range 215-265 |
|
Dual Output Power Supplies
POWER SUPPLY MODEL (Click for Spec Sheet)
|
OUTPUT 1 |
OUTPUT 2 |
CASE SIZE |
Click on code for Case details |
|||
IHAA5-1.5/OVP |
5V @ 1.5A |
-5V @ 1.5A |
|
Overvoltage Protection Provided (both outputs) | |||
5V @ 3A |
-5V @ 3A |
||
Overvoltage Protection Provided (both outputs) | |||
5V @ 6A |
-5V @ 6A |
||
Overvoltage Protection Provided (both outputs), Remote Sense Provided | |||
12V @ 0.4A |
-12V @ 0.4A |
||
Non-adjustable 3 Terminal Regulator | |||
15V @ 0.4A |
-15V @ 0.4A |
||
Non-adjustable 3 Terminal Regulator | |||
12V @ 1A or 15V @ 0.8A |
-12V @ 1A or -15V @ 0.8A |
||
Remote Sense Provided | |||
12V @ 1.7A or 15V @ 1.5A |
-12V @1.7A or -15V @ 1.5A |
||
Remote Sense Provided | |||
12V @ 3.4A or 15V @ 3.0A |
-12V @ 3.4A or -15V @ 3.0A |
||
Remote Sense Provided | |||
12-15V @ 5A |
-12-15V @ 5A |
||
Remote Sense Provided | |||
IHAA24-0.6 |
18-20V @ 0.4A or 24V @ 0.6A |
-18-20V @ 0.4A or -24V @ 0.6A |
|
18-20V @ 0.9A or 24V @ 1.2A |
-18-20V @ 0.9A or -24V @ 1.2A |
||
IHCC24-2.4 |
18-20V @ 1.8A or 24V @ 2.4A |
-18-20V @ 1.8A or -24V @ 2.4A |
|
Remote Sense Provided | |||
IHAA512 |
5V @ 2A |
12-15V @ 0.5A |
|
Overvoltage Protection Provided (5V output only) | |||
IHD12-6.8-504 |
5V @ 3A |
12V @ 6A |
|
Overvoltage Protection Provided (5V output only) | |||
5V @ 3A |
12-15V @ 1.5A |
||
Overvoltage Protection Provided (5V output only), Remote Sense Provided | |||
IHCC512 |
5V @ 6A |
12-15V @ 2.5A |
|
Overvoltage Protection Provided (5V output only), Remote Sense Provided | |||
ICP323 |
5V @ 2A |
12V @ 4A |
|
Overvoltage Protection Provided (5V output only) | |||
ICP510 |
5V @ 6A |
12V @ 2.5A / 7.5APK |
|
Overvoltage Protection Provided (5V output only) |
Triple Output Power Supplies
POWER SUPPLY MODEL (Click for Spec Sheet)
|
OUTPUT 1 |
OUTPUT 2 |
OUTPUT 3 |
CASE SIZE |
Click on code for Case details |
||||
5V @ 2A |
12-15V @ 0.4A |
-12-15V @ 0.4A or -5 @ 0.4A |
||
Overvoltage Protection Provided (output 1) | ||||
IHBAA-40W |
5V @ 3A |
12V @ 1A or 15V @ 0.8A |
-12V @ 1A or -15V @ 0.8A or -5V @ 0.4A |
|
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
IHCAA-60W |
5V @ 6A |
12V @1A or 15V @0.8A |
-12-15V @1A or -5V @ 0.4A |
|
Overvoltage Protection Provided (output 1), Remote Sense Provided (output 1) | ||||
5V @ 6A |
12V @ 1.7A or 15V @ 1.5A |
-12V @ 1.7A or -15V @ 1.5A or -5 @ 0.7A |
||
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
5V @ 3A |
12V @ 3.4A or 15V @ 3A |
-12V @ 3.4A or -15V @ 3A |
||
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
IHBCC524 |
5V @ 3A |
18-20V @ 1.8 or 24V @ 2.4A |
-18-20V @ 1.8 or -24V @ 2.4A |
|
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
5V @ 8A |
12V @ 1.7A or 15V @ 1.5A |
-12V @ 3.4A or -15V @ 3A or -5 @ 0.7A |
||
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
5V @ 12A |
12V @ 1.7A or 15V @ 1.5A |
-12V @ 1.7A or -15V @ 1.5A or -5 @ 0.7A |
||
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
5V @ 12A |
12V @ 3.4A or 15V @ 3A |
-12V @ 3.4A or -15V @ 3A |
||
Overvoltage Protection Provided (output 1), Remote Sense Provided (all outputs) | ||||
High Power AC to DC Power Supplies Voltage/Current Rating Chart
MODEL |
OUTPUT #1 |
OUTPUT #2 |
OUTPUT #3 |
OUTPUT #4 |
CASE SIZE |
---|---|---|---|---|---|
ICP323 |
5V@2A* |
12V@4A |
|||
ICP162 |
5V@3A* ‡ |
-5V@0.6A* |
24V@5A / 6A PK ‡ |
||
ICP510 |
5V@6A* |
12V@2.5A / 7.5A PK ‡ |
|||
ICP379 |
5V@6A* ‡ |
-5V@1.2A or -12V@1.2A |
24V@3.5A / 8A PK ‡ |
||
ICP384 |
5V@9A* ‡ |
-5V@1.2A or -12V@1.2A |
24V@2A / 8A PK ‡ |
||
ICP503 |
5V@6A* |
12V@1.2A |
-12V@0.8A |
24V@2.5A / 4A PK |
* Overvoltage Protection Provided ‡ Remote Sense Provided
Unregulated Power Supply Line IP500U SERIES
The IP500U series unregulated power supply line is designed for high current applications at low cost when full regulation is not required. This rugged, highly reliable power supply line is ideal for applications such as powering solenoids, relays, DC motors, lamps and DC-DC converters. Standard DC outputs are listed below, other outputs from 9 to 175 volts are available on special order. | |
Standard Features |
- Bobbin Wound Transformer
- Computer Grade Capacitors
- Floating Output
- Full Rated to 55 degrees Celsius
- Open Frame Construction
- Secondary Fuse Protection
- 50 amp, 200 volt full bridge rectifier
- Full two year warranty
- MECHANICAL DRAWING
Specifications
- AC Input 47-63 Hz
- 108/120/132/216/240/264 VAC Selection
- Output Ripple: 3% RMS at full rated load, 4% on 12 volt model IP500U12
- Efficiency @ Full Load 80% typical
- UL Recognized for USA and Canada File Number E133338
- Complies with the requirements of standard EN 60590 and low voltage directive 72/23/EEC
TYPICAL DC OUTPUT @ NOMINAL INPUT
MODEL NUMBER |
NO LOAD |
HALF LOAD |
FULL LOAD |
AMPS FULL LOAD |
14.7 |
13.0 |
12.0 |
30 |
|
IP500U24 |
29.2 |
26.8 |
24.6 |
20 |
IP500U36 |
42.8 |
38.2 |
36.1 |
13.3 |
IP500U48 |
56.6 |
52.8 |
48.8 |
10 |
IP500U65 |
75.2 |
68.8 |
65.2 |
7.7 |
IP500U75 |
85.5 |
78.2 |
74.8 |
6.6 |
Overvoltage Protectors
OVP Selection Guide (DATA SHEET)
MODEL |
CASE SIZE |
OVP MODULES REQUIRED |
SINGLE OUTPUT | B, C, N, D, E, F NOTE: IOVP-12 & IOVP-24: Adj Range: 6.5 to 35 V | IOVP-12 IOVP-24 |
DUAL OUTPUT | AA, B, BB, CC, E, DD | IOVP-12 protects both outputs.OVP built-in on 5V outputs.IOVP-24 protects both outputs. |
TRIPLE OUTPUT | AA, BAA, D, CBB, 131, DBB | IOVP-12 protects both 9V thru 15V outputs.OVP built-in on main 5V outputs. |
HIGH POWER MODELS | N, BAA, CBB, 131, 510 | IOVP-12 protects any output.Not provided with built-in OVP. |
IAR5-0.6/OVP, -5 V Sub-Regulator ModuleThe IAR5-0.6/OVP will provide a -5 VDC regulated output @0.6 amps when connected to any filtered -7 to -30 DC source. |